PlasmaQuant 9200 Series Compact Size. Peak Performance.
- Analytical excellence – Unparalleled resolution of 2 pm @ 200 nm and best detection limits with long-term stability
- Space-saving powerhouse – Fast instrument start-up, robust plasma and the smallest footprint on the ICP-OES market
- Simply reliable – Effortless handling, easy consumable replacement, and full flexibility
Discover market-leading resolution with unmatched matrix tolerance in a compact analyzer. Enjoy efficiency, easy handling, and the smallest footprint in the ICP-OES market.
The Benchmark in ICP-OES
Thanks to its unique instrument design and stable plasma flame, the PlasmaQuant 9200 series offers not only the highest resolution and best detection limits for any sample type, but also the smallest instrument footprint. In combination with unmatched reliability and easy handling, Analytik Jena's new ICP-OES instrument will be the key for your successful labwork.
- Unparalleled resolution, best detection limits with long-term stability and the most extensive spectral range available
- Flexible plasma observation and up to 1,700 watt of plasma power
- Smallest footprint on the ICP-OES market saving more than 40% of laboratory space compared to the predecessor
- Fast device start-up time of less than ten minutes
Brochures
Title | Language | Info |
---|---|---|
Broschüre PlasmaQuant 9200 Serie (DE) | de | PDF, 4 MB |
Brochure PlasmaQuant 9200 Series (EN) | en | PDF, 4 MB |
Best Performance and Reliability in a Compact Design
An optical emission spectrophotometer that is designed for those who expect nothing less than the highest precision, reliability and sensitivity. Whether it is cutting edge research, finding every trace in quality control, or anything in between. The PlasmaQuant 9200 series is at your side.
Analytical Excellence
The PlasmaQuant 9200 series combines market-leading resolution with unsurpassed matrix tolerance – that way, your results meet the highest analytical standards.
- With unparalleled resolution of 2 pm @ 200 nm, the peak is always in plain sight
- Best detection limits with long-term stability for reliable results
- Adapt to any challenge with the most extensive spectral range available – 160 to 900 nm for ultimate versatility
Space-Saving Powerhouse
Quick instrument start-up, robust plasma and the smallest footprint on the market – with the PlasmaQuant 9200 series you not only save time and money, but also valuable lab space.
- We reduced the instrument size by more than 40 percent, making the PlasmaQuant 9200 the smallest instrument in its class, with only 60 cm width
- Master any matrix with up to 1,700 Watt of plasma power
- Save time and resources with quick boot-up time of less than 10 minutes
Simply Reliable
Effortless handling, easy consumable replacement, and long-term reliability. The PlasmaQuant 9200 series ensures carefree use, application safety, and full flexibility.
- Mix and match your torch – Depending on your samples, use the material that fits best, with our completely modular solution
- The Dual View PLUS allows to measure each sample with the optimum plasma observation modes to avoid repetitive sample measurements
- With a tailor-made service contract, you are always on the safe side, be it for regular maintenance for more sustainability or quick help when you need it
Products
PlasmaQuant 9200
Cost-effective analysis without compromises
Order number: 818-09200-2
PlasmaQuant 9200 Elite
High spectral resolution for challenging applications
Order number: 818-09201-2
Applications
Applications
-
Direct Analysis of Saline Matrices by HR ICP-OES (EN)
-
Monitoring Drinking Water Quality With High Resolution ICP-OES (EN)
Applications
-
Analysis of Elemental Impurities in Diesel by HR ICP-OES According to ASTM D7111-16 (EN)
Technical Data
Detector |
Wavelength precision |
Plasma observation |
Number accessible emission lines |
Power range RF generator |
FWHM values |
Spectral resolution |
Wavelength range |
Optical design |
Dimension (width x depth x height) |
|
---|---|---|---|---|---|---|---|---|---|---|
PlasmaQuant 9200 |
Charge Coupled Device (CCD) | < 0.4 pm via internal Ne-correction | Radial plus, axial plus | > 43,000 | 700 - 1700 W | ≤ 5.0 pm for As 193.696, Tl 190.796 | 0.006 nm at 200 nm | 160 - 900 nm | Echelle Double Monochromator | 600 mm x 809 mm x 932 mm |
PlasmaQuant 9200 Elite |
Charge Coupled Device (CCD) | < 0.4 pm via internal Ne-correction | Radial plus, axial plus | > 43,000 | 700 - 1700 W | ≤ 3.5 pm for As 193.696, Tl 190.796 | 0.002 nm at 200 nm | 160 - 900 nm | Echelle Double Monochromator | 600 mm x 809 mm x 932 mm |
For more information about our products and possible variants, please refer to the technical documents or use our contact form.
Standards
- 1881/2006 of the EU
- AOCS Ca 17-0
- ASTM D4806
- ASTM D4951
- ASTM D5185
- ASTM D5708
- ASTM D7111-15a
- ASTM D7111-16
- ASTM D7691
- DIN EN 14538
- DIN EN 15376:2014-12
- DIN EN 15837:2010-04
- DIN EN 16174:2012-11
- DIN EN 228:2017-08
- DIN EN ISO 11885 (E22)
- GB/T 11064.16
- IEC-62321
- ISO 10540-3
- ISO 21033
- ISO 22241
- ISO-11885:2007
- UOP 796
- UOP-296
Order Information
Order number |
Description |
---|---|
818-09200-2 | PlasmaQuant 9200 |
818-09201-2 | PlasmaQuant 9200 Elite |
Technology at the Highest Level for Demanding Routine Analyses
High-Resolution Optics – Maximum Sensitivity – Ultimate Confidence in Your Results
The advanced optical system delivers exceptional resolution, enabling outstanding sensitivity, precision, and accuracy – even in the most complex sample matrices. The proven encapsulated echelle spectrometer combines a dual monochromator with a powerful high-resolution CCD detector, providing full access to all emission lines across the 160 to 900 nm spectral range. With a spectral resolution of up to 2 pm @ 200 nm, even the most challenging interferences can be reliably separated. With over 43,000 selectable lines, you can pinpoint the ideal emission line for your application and gain deeper insights into your samples. High sensitivity from interference-free lines ensures robust trace element analysis and maximum result reliability. The automatic neon correction guarantees a wavelength accuracy of less than 0.4 pm – without the need for elaborate calibration – and delivers system readiness in under 10 minutes.
Your benefits:
- Maximum flexibility thanks to a comprehensive selection of emission lines
- Interference-free spectra for precise results
- Reliable detection even in complex sample matrices
- Fast system readiness with short startup times
Intuitive Operation – The V Shuttle Torch
The modular V Shuttle Torch with plug-and-play design simplifies maintenance and increases system uptime. Interchangeable components allow for flexible method adaptation while reducing consumables costs. All gas connections automatically engage as the torch clicks precisely into the guide rail – no tools required. The vertical plasma setup enables highly precise analysis of matrix-rich samples without the need for time-consuming pre-dilution and ensures minimal background signals. Even under harsh conditions, the system provides excellent long-term stability – free from deposits or soot buildup.
Your benefits:
- Reduced maintenance and increased availability
- Broad application scope with strong analytical performance
- Efficient use of consumables
- Torch replacement without alignment
Flexible Plasma Observation – Dual View PLUS
Trace and major elements require different plasma viewing modes. Dual View PLUS allows axial or radial observation for each emission line – offering two perspectives per sample. This enables detection of concentrations ranging from the sub-ppb to high-percent levels. Automatic signal attenuation in both viewing directions ensures an exceptionally wide dynamic range. Integrated counter-gas technology minimizes interference from the cooler plasma tail while maintaining the stability of the axial viewing zone. The result: high-sensitivity analysis with minimal sample preparation effort.
Your benefits:
- Optimal observation modes for every application
- Counter-gas technology for enhanced sensitivity
- Single-run detection from sub-ppb to percent levels
- Minimal sample preparation required
A Technological Edge – The Latest Generation RF Generator
The modern 27 MHz RF generator delivers highly stable and powerful plasma – even for demanding sample matrices. Low matrix-specific detection limits, reduced sample handling, and robust methodologies significantly enhance the precision and efficiency of your analysis. The high-performance three-turn coil supports a power range from 700 to 1700 Watt, making it ideal for routine industrial applications such as brines, metal concentrates, or volatile organics. Thanks to its short warm-up time, the system is ready for use within minutes.
Your benefits:
- Stable plasma generation for any sample matrix
- Accurate results without dilution steps
- Maximum flexibility for changing applications
- Reliable detection even in challenging sample types
Accessories
SALT KIT for PlasmaQuant 9x00 series | 810-88561-0 |
ORGANIC KIT for PlasmaQuant 9x00 series | 810-88562-0 |
HF KIT for PlasmaQuant 9x00 series | 810-88007-0 |
STANDARD KIT for PlasmaQuant 9x00 series | 810-88006-0 |
PRECISION KIT for PlasmaQuant 9200 Elite | 810-88010-0 |
Cetac ASXPress Plus (aq) 6-port valve for aqueous samples | 810-88120-0 |
Cetac ASXPress Plus (oil) 6-port valve for oil samples | 810-88121-0 |
Connector (PP, 2,5 mm ID) for wash reservoir ASPQ 3300 | 418-10-405-012 |
Enclosure ENC-560 DC for Teledyne Cetac ASX-560 | 810-88063-0 |
ESI Enclosure with ULPA Filter for Autosampler SC-4 DX Basic FAST | 810-88103-0 |
HEPA Filter for Enclosure ENC-560 and ENC 860 DC | 810-88064-0 |
Kit septum piercing complete for ASPQ 3300 | 418-10-405-013 |
Protective cover for autosampler ASPQ 3300 | 810-88003-0 |
Teledyne Cetac SDXHPLD Upgrade Kit for ASX-560 | 810-88519-0 |
Autosampler Upgrade Kit - ASPQ for 192 positions, set of 3 pcs | 810-88524-0 |
Water-air-chiller (Labtech) for ICP-OES and ICP-MS | 810-88001-0 |
Water-Water-Chiller (vdH) for ICP-OES and ICP-MS | 810-88036-0 |
Argon humidifier with bypass for PlasmaQuant 9x00 series | 810-88033-0 |
Elegra Membrane | 810-88526-0 |
Exhaust hose ICP-OES for PlasmaQuant 9x00 series | 810-88109-0 |
EzyLok Kit for Argon hum. | 810-88525-0 |
Ratchet EzyLok Connector | 810-88527-0 |
Extraction Kit ICP-OES | 810-88115-0 |
Hydride system HS PQ for PlasmaQuant 9x00 series | 810-88030-0 |
Hydride system HS Pro PQ for PlasmaQuant 9x00 series | 810-88032-0 |
Bench for ICP - heavy duty, short | 810-88112-0 |
Bench for ICP/AAS for AAS, ICP-OES and ICP-MS instrumentation | 810-88005-0 |
Teledyne-Cetac ASX-280 autosampler for ICP-OES | 810-88544-0 |
Teledyne-Cetac ASX-560 autosampler for ICP-OES and ICP-MS | 810-88015-0 |
Teledyne Cetac Oils 7400 | 810-88122-0 |
Teledyne Cetac SDXHPLD with ASX-560 Autosampler | 810-88123-0 |
Teledyne Cetac SimPrep with ASX-560 Autosampler | 810-88019-0 |
Software
ASpect PQ
ASpect PQ Software – Smart Control for Maximum Efficiency
ASpect PQ software centrally controls, monitors, and documents all processes within the PlasmaQuant 9200 system – with precision, reliability, and ease of use. Its modular architecture offers the flexibility to work with predefined routine methods or to develop custom methods tailored to specific analytical needs.
Powerful automated tools such as Automatic Baseline Correction (ABC) and Correction for Spectral Interferences (CSI) streamline data evaluation, eliminate guesswork, and significantly boost laboratory productivity. A clear, multilingual user interface allows you to quickly configure matrix-specific methods by simply selecting the elements and preferred emission lines. All essential method parameters are automatically loaded and can be easily adjusted.
Note: With the launch of the new PlasmaQuant 9200, ASpect PQ has received a targeted update – enhancing its stability, usability, and overall performance.
Your benefits at a glance:
- Advanced routines for method optimization, evaluation, and recalculation
- Fully compliant with 21 CFR Part 11 – including an updated FDA module and user management
- Innovative automation features like ABC and CSI for reliable data quality
- Seamless LIMS integration for efficient data transfer
ASpect PQ meets all regulatory requirements, including FDA compliance. User rights can be flexibly configured, and system access is secured via personal passwords or Active Directory. All key events – such as logins, measurements, calibrations, and system checks – are recorded in a detailed audit trail. Electronic signatures support routine review and approval of measurement data.
Product | Required | Included |
---|---|---|
PlasmaQuant 9200 (818-09200-2) | ||
PlasmaQuant 9200 Elite (818-09201-2) |
Consumables
810-88042-0 | Consumables Set HF Kit for PlasmaQuant 9x00 series |
810-88044-0 | Consumables Set Organic Kit for PlasmaQuant 9x00 series |
810-88560-0 | Consumables Set Precision Kit for PlasmaQuant 9200 |
810-88046-0 | Consumables Set Salt Kit for PlasmaQuant 9x00 series |
810-88040-0 | Consumables Set Standard Kit for ICP-OES |
418-13-410-595 | Set of PVC-pump tubing (blk/blk),flared, for hydride reducing agent |
418-13-410-393 | Set of PVC-pump tubing (red/red) for waste |
418-13-410-392 | Set of PVC-pump tubing for sample (black/black) |
418-13-410-532 | Set pump tubing viton (black/black) for sample |
418-13-410-533 | Set pump tubing viton red/red for waste |
418-13-410-617 | Set PVC pump tubing (violet/orange) for waste of hydride system |
418-88097-0 | Set tube connector nebulizer gas for ICP-OES and ICP-MS |
418-10-1700-163-20 | Tubing set for HS PQ |
418-10-1700-162-20 | Tubing set for HS PQ Pro |
418-13-5850-307-10 | HV-deflector spring |
418-13-5850-340-10 | Filter element plasma chamber |
418-13-5850-682-00 | Axial window, quartz |
418-13-5850-680-14 | Axial window with cone complete |
418-13-5850-685-14 | Axial window with Ni-cone (complete) |
418-13-410-398 | hook wrench for cone on PlasmaQuant 9x00 series |
418-13-410-349 | Inlet air filter element |
418-13-5850-006-20 | Radial window, complete |
418-13-410-411 | Radial window, quartz glass |
418-13-410-438 | Water filter cartridge for cooling water cycle on PlasmaQuant 9x00 series |
418-13-410-343 | O-Ring 22x2 for axial window |
418-13-410-538 | O-Ring for One-piece torch 13 x 3,5 |
418-13-410-537 | O-Ring for One-piece Torch 20 x 2 |
418-13-410-555 | O-Ring one-piece torch for aqueous solution |
418-13-410-612 | O-Ring one-piece torch for organic samples |
418-13-5850-007-20 | O-ring set for radial window |
418-10-405-526 | O-rings for Nebulizer cleaning tool |
418-13-5850-011-20 | Set O-rings for demountable torch for ORGANIC KIT |
418-13-5850-010-20 | Set O-rings for demountable torch for STANDARD KIT, HF KIT, SALT KIT |
418-13-5850-008-20 | Set o-rings for mounting base torch on basic ICP-OES unit |
418-13-5850-009-20 | Set O-rings torch body for V Shuttle Torch |
407-10-1700-101-11 | Bottle reducing agent, 1L for ICP/AAS hydride systems |
418-13-410-540 | cooling water additives (2 components) |
418-13-410-592 | Kit internal Std addition for HF KIT |
418-13-410-593 | Kit internal Std addition for STANDARD KIT, ORGANIC KIT, SALT KIT |
418-10-406-210 | Adapter for Inline Filter for tubing (1,3mm) |
418-13-410-403 | Ball Joint Adapter Polypropylene with 2 different O-rings |
418-10-1700-167-11 | check valve, complete for Hydride systems HS PQ and HS PQ Pro |
418-10-405-165 | Cleaning tool for concentric nebulizer HF KIT |
418-13-410-406 | concentric nebulizer,1mL/min Borosilicate glass |
418-13-410-482 | concentric nebulizer 0.1mL/min borosilicate glass |
418-13-410-480 | concentric nebulizer 0.4mL/min Borosilicate glass |
418-13-410-484 | concentric nebulizer 1mL/min Borosilicate glass, for high salt content |
418-13-410-485 | concentric nebulizer 1mL/min PEEK |
418-13-410-609 | concentric nebulizer 2mL/min Borosilicate glass, for high salt content |
418-13-410-486 | concentric nebulizer PEEK 0.4 mL/min |
418-13-410-597 | concentric nebulizer PFA 1mL/min |
418-13-410-663 | Connector for nebulizer 4mm |
418-88216-0 | Connector for parallel path nebulizer |
418-13-410-416 | Cyclonic spray chamber, 20 mL Borosilicate glass |
418-13-410-407 | Cyclonic spray chamber, 50mL Borosilicate glass |
418-13-410-414 | Cyclonic spray chamber, 50 mL with dip tube Borosilicate glass |
418-10-406-043 | Cyclonic spray chamber, 50 mL with two inlets, Borosilicate glass |
418-13-410-415 | Cyclonic spray chamber PTFE 50 mL |
418-10-405-010 | Fixed probe guide / vial stop for septum piercing accessory ASPQ 3300 |
418-10-405-018 | Kit wash reservoir 95 mm for ASPQ 3300 |
418-10-405-177 | Nebulizer for tubing for Salt kit |
418-10-405-176 | Nebulizer tubing for Standard Kit, Organic Kit, HF-Kit |
418-10-405-175 | Nebulizer tubing organic samples for ICP-OES |
418-13-410-598 | parallel path nebulizer 1mL/min PFA |
810-88559-0 | Precision Nebulizer for PlasmaQuant 9200 Elite |
418-13-400-015 | PTFE Waste tubing (Extension; 1m; 1.6x1.0mm) |
418-13-410-528 | PU pump tubing (black/black) for sample |
418-13-410-529 | PU tubing (red/red) for waste |
418-10-405-946 | Ratchet EzyLok Connector |
418-10-405-009 | Sample probe septum piercing for ASPQ 3300 |
418-13-410-594 | Set of PVC-pump tubing (red/red) flared for waste |
418-13-410-590 | Transfer Tube for Isomist |
418-10-405-166 | Waste tubing for cyclonic spray chamber |
418-13-5850-900-14 | demountable V Shuttle Torch complete with 2mm injector |
418-13-5850-922-10 | Glas Torch (one piece) one-piece torch, quartz glass, injector 2mm |
418-13-410-408 | Injector 1.0mm; Quartz glass for V Shuttle Torch |
418-13-410-412 | Injector 2.0mm, Alumina for V Shuttle Torch |
418-13-410-404 | Injector 2.0mm, Quartz glass for V Shuttle Torch |
418-13-410-596 | Inline Filter for tubing (1,3mm) for PQ 9x00 series |
418-13-410-401 | Inner tube, Quartz glass for V Shuttle Torch |
418-13-410-492 | Inner tube (Alumina ceramic) for V Shuttle Torch |
418-13-410-657 | Lubricated cloth for demountable torch |
418-13-410-402 | Outer tube, Quartz glass for V Suttle Torch |
418-13-410-491 | Outer tube (Syalon) for V Shuttle Torch |
418-13-5850-908-10 | Outer tube slotted Quartz glass |
418-13-410-400 | Torch body, Quartz for V Shuttle Torch |
418-13-5850-925-10 | Torch Bonnet, large for PlasmaQuant 9x00 series |
418-13-5850-001-20 | V Shuttle (PTFE) with Torch Body for V Shuttle Torch |
418-13-5850-910-14 | V Shuttle with one-piece torch quartz glass, injector 2mm |
418-88121-0 | 1,5 ml sample loop connects |
418-88141-0 | 1.0 ml Sample Loop ID 2mm for Cetac ASXPress Plus aqueous |
418-88116-0 | 1mL sample loop for ESI FAST |
418-88123-0 | 2,5 ml sample loop connects |
418-88173-0 | 2.00 ml Sample Loop ID 1mm for Cetac ASXPress Plus organic |
418-88142-0 | 2.0 ml Sample Loop ID 2mm for Cetac ASXPress Plus aqueous |
418-88151-0 | 2-Channel Peristaltic Pump Cartrige Tubing Pharmed, ID 2.2 mm for ASX 560 |
418-88211-0 | 2-Channel Pump TubingCartridge 3.3 mm ID Pharmed equivalent for Cetac Oils 7x00 peristaltic pump |
418-88212-0 | 2-Channel Pump TubingCartridge 3.3 mm ID Viton equivalent for Cetac Oils 7x00 peristaltic pump |
418-88122-0 | 2 ml sample loop connects 2ml sample loop for sample introduction systems |
418-88143-0 | 3.0 ml Sample Loop ID 2mm for Cetac ASXPress Plus aqueous |
418-88124-0 | 3 ml sample loop connects |
418-88144-0 | 4.0 ml Sample Loop ID 2mm for Cetac ASXPress Plus aqueous |
418-88125-0 | 4 ml sample loop connects |
418-88145-0 | 5.0 ml Sample Loop ID 2mm for Cetac ASXPress Plus aqueous |
418-10-405-335 | Ansaugkanüle PTFE Sample Probe, PTFE sleeved, for sampler SPS-3 |
810-88126-0 | ASX-560 Consumable Kit for one year operation |
418-88224-0 | ASX-560 Oil Upg. Kit -new Pump Tubing assembly Kit to use ASX 560 for Oil matrices new DP2 pump |
418-88210-0 | Barb Fitting for Rinse Station of Cetac Oils 7x00 series |
418-88108-0 | carbon fibre probe, 0.5mm id teflon sleeved, for ASPQ3300 |
418-88098-0 | carbon fibre probe, 0.5mm id teflon sleeved, for ASX-560 autosampler |
418-88109-0 | carbon fibre probe, 0.8mm id teflon sleeved, for ASPQ3300 |
418-88107-0 | carbon fibre probe, 0.8mm id teflon sleeved, for ASX-560 autosampler |
418-88110-0 | carbon fibre probe, 1.0mm id teflon sleeved, for ASPQ3300 |
418-88217-0 | carbon fibre probe, 1mm id teflon sleeved (blue-blue band), for ASXPRESS |
418-88114-0 | carrier Probe oneFAST |
418-88179-0 | Carrier Solution Tee Assembly for ASXPRESS Plus aqueous |
418-8819-0 | Cetac Dual Rinse Station for ASX-560 |
418-88111-0 | Cetac ASX-560 Rinse station |
418-88100-0 | Drain Pump Tubing (PharMed) for ASX 560 (waste tubing) |
418-88128-0 | ESI FAST probe Cetac ASX5X0 Probe CETAC ASX-5xx for ESI FAST system |
418-88127-0 | ESI Probe ASPQ3300 Probe ASPQ3300 for ESI FAST system |
418-88112-0 | ESI SC-FAST Ansaugkanule, 0.8m ESI SC-FAST autosampler probe, 0.8mm ID, blue marker |
418-88113-0 | ESI SC-FAST Ansaugkanule, 1.0m ESI SC-FAST autosampler probe, 1.0mm ID, grey marker |
418-88192-0 | Ferrule Kit for ASXPRESS Plus |
418-88191-0 | Fittings Kit for ASXPRESS Plus |
418-10-5090-014-20 | holder cannula carbon with nut for demountable sample probe ASPQ 3300 |
418-88135-0 | Internal Standard Line, P7 Val |
418-88133-0 | Internal Standard Tee 0.25ID |
418-88134-0 | Internal Standard Tee 0.5ID |
418-88126-0 | Internal Std. Probe f. oneFAST Probe internal Standard, 0.5 mm ID for SCFAST |
418-10-405-155 | Kit wash reservoir ASPQ 3300 |
418-88188-0 | Mixing Tee for Internal Std. Addition ASXPRESS PLUS |
418-88193-0 | Nickel-Plated Tee ConnectorKit for ASXPRESS oil |
418-88198-0 | O-Ring Vortex Mixer and Vessel for Cetac SDXHPLD |
418-88189-0 | Passive Bubbling Tee for ASXPRESS Plus and clinPAL |
418-10-405-333 | Probenrack ICP; 24 Positionen |
810-88125-0 | Rack Kit 84 Positions for ASPQ 3300, ASX-560 and SC-4 DX autosamplers |
418-88213-0 | Rinse/Drain Tubing Hookup Kit 4.8mm ID for Cetac Oils 7x00 series |
418-88214-0 | Rinse/Drain Tubing Hookup Kit 4.8mm ID for Cetac Oils 7x00 series |
418-88164-0 | Rinse/drain Tubing Hookup Kit ASX 560, Tygon |
418-88165-0 | Rinse/drain Tubing Hookup Kit ASX 560, Tygon FEP-lined |
418-88207-0 | Rinse station for Oils 7x00 series |
418-88199-0 | Rinse Tubing Kit SyringeModule for Cetac SDXHPLD |
418-10-405-336 | Sample Probe, demountable complete Carbon; for autosampler ASPQ 3300, SPS-3 |
418-88228-0 | Sample Rack ICP, 21 positions, 50ml vials |
418-88227-0 | Sample Rack ICP, 40 positions, 20 mL vials |
418-88226-0 | Sample Rack ICP, 60 positions, 14 ml vials |
418-88223-0 | Sample Rack ICP, 90 positions, 8ml vials |
418-13-410-698 | Set pump tubing (grey/grey) Fluoro rubber; for ASPQ 3300 autosampler |
418-13-410-541 | Set pump tubing (grey/grey) for ASPQ 3300 autosampler |
418-10-5090-012-20 | Set sample aspiration tubing for demountable sample probe ASPQ 3300 |
418-88202-0 | Stainless Steel Sample Probe w/Filtered Tip for Cetac Oils series |
418-10-405-328 | Standard Rack Kit, 6 Position for 50 mL tubes, 30mm ID |
418-88203-0 | Stirrer Paddle for Cetac Oils 7x00 series |
418-88115-0 | ST nebulizer line for SC-FAST |
418-88169-0 | Syringe to Diluent Tubing for Cetac SimPrep |
418-88170-0 | Syringe to Probe Tubing for Cetac SimPrep |
418-10-405-149 | Tube anchor (X-axis) for ASPQ 3300 |
418-88234-0 | Tube Nut, fem, 1/4-28 AIM |
418-88168-0 | Valve Cross Tube Assembly for Cetac SimPrep |
418-88186-0 | Valve Pump Tubing Kit for ASXPRESS Plus aq |
418-88187-0 | Valve Pump Tubing Kit for ASXPRESS Plus oil |
418-88931-0 | Z-Axis Tubing Replacement Kit |
418-88119-0 | 0,25 ml sample loop connects |
418-88120-0 | 0,5 ml sample loop connects 0.5 mL sample loop for ESI FAST |
Downloads
The newsletter of Analytik Jena frequently keeps you posted about:
- News
- Trends and developments
- Events