novAA series | contrAA series | ZEEnit series | Accessories | Applications | Publications | Download | Brochures
Accessories to Atomic spectrometry systems::.
|
Autosamplers for the flame mode, hydride techniques and atomic fluorescence
Autosamplers for the flame mode AS 51s and AS 52s Integrated in the overall concept of the instrument, either sampler can be simply hung directly into the sample compartment: The intelligent dilution function of the AS 52s makes manual dilution, a time-consuming and error-prone process, unnecessary. Automatically, it dilutes your samples down to a factor of 1:625. If concentrations exceed the calibration range, an automatic clean control prevents contamination of the subsequent samples. | |  AS 52s
|
|
top
 | Autosampler for graghite furnace — more than only a sampler
With the MPE 60 z, the autosampler for graphite furnace AAS of liquid samples, automated sample preparation and analysis are easy: Automatic generation of reference curves from one or several stock solutions (up to ten points) Dosing of extremely small sample volumes with excellent repeatability Automatic sample dilution and enrichment by a specified factor Intelligent automatic dilution of samples exceeding the alibration range; clean control limits to avoid contamination Automatic enrichment of samples below the calibration range Unique automatic correction of the immersion depth for every vessel containing sample or other liquid Robust, low-noise operation Fast, easy adjustment
Its many functions and the automatic running of optimizing routines make the MPE 60 z an intelligent sample preparation. |
|  MPE 60 z
|
|
top
 | Automatic and manual feeding — direct analysis of solids
Automatic feeding — SSA 600
Automated insertion of the loaded platform into the furnace Fully automatic weighing with an integrated microbalance Up to 80 positions availability Choice of different modes of operation
Manual feeding — SSA 6 z | |  SSA 600
|
|
top
 | Mercury/ Hydride systems
The measurement and monitoring of mercury and such elements as arsenic or selenium down to low ppb concentrations has always been a challenge. In order to keep the amount of these toxic substances under control in the environment, fast methods and convenient, yet flexible systems are required. If the hydride systems are coupled with the graphite furnace (HydrEA technology), completely new perspectives open up for the measurement of hydride forming elements (such as As, Se, Sb). The option of enrichment in the graphite tube raises detection sensitivity and contamination problems are minimised. | |  Hydride system
|
|
top
 | Other accesories
Scraper The "Scraper" is an intelligent, automatic, software controlled cleaning device for the nitrous oxide burner head for troublefree work over a long period. Injection module SFS 6 Highly proven performance of optimized accessories like the injection module SFS 6 make the application of extensive samples with high salt content easier. HPT Burner Improvement of sensitivity by increasing time of stay of the atom cloud in the flame, Quartz or Titanium tube in the top of the slit.
| |  Injection module Scraper
Burner
|
|
|
|
|